Barrett, The Honors College Thesis/Creative Project Collection


Barrett, the Honors College accepts high performing, academically engaged students and works with them in collaboration with all of the other academic units at Arizona State University. All Barrett students complete a thesis or creative project, supervised and defended in front of a faculty committee. The thesis or creative project allows students to explore an intellectual interest and produce an original piece of scholarly research. The thesis or creative project is a student’s opportunity to explore areas of academic interest with greater intensity than is possible in a single course. It is also an opportunity to engage with professors, nationally recognized in their fields and specifically interested and committed to working with honors students. This work provides tangible evidence of a student’s research, writing and creative skills to graduate schools and/or prospective employers.


Date Range
2013 2017


This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work to render the Stentzor deployable in live subjects, including [1] further design optimization, [2] electrical isolation, [3] wireless data transmission, and [4] testing for aneurysm prevention.

Contributors
Meidinger, Aaron Michael, LaBelle, Jeffrey, Frakes, David, et al.
Created Date
2014-05

Development of a rapid and label-free Electrochemical Impedance Spectroscopy (EIS) biosensor for Cardiovascular Disease (CVD) detection based on Inerluekin-18 (IL-18) sensitivity was proposed to fill the technology gap between rapid and portable CVD point-of-care diagnosis. IL-18 was chosen for this CVD biosensor due to its ability to detect plaque vulnerability of the heart. Custom (hand) made sensors, which utilized a three electrode configuration with a gold disk working electrode, were created to run EIS using both IL-18 and anti-IL-18 molecules in both purified and blood solutions. The EIS results for IL-18 indicated the optimal detection frequency to be 371Hz. Blood ...

Contributors
Jha, Amit, LaBelle, Jeffrey, Mossman, Kenneth, et al.
Created Date
2013-05

Cerebral aneurysms are pathological bulges in blood vessels of the brain that can rupture and cause brain damage or death. Treating aneurysms by isolating them from circulation can prevent aneurysm rupture. Endovascular techniques for cerebral aneurysm treatment are preferred because they are minimally invasive and have a shorter recovery time, and endovascular coiling is considered the gold standard as a result. The coils used in endovascular treatment come in standard shapes and sizes, mass-manufactured by medical device companies. Clinicians select the coils for treatment based on the aneurysm volume. However, cerebral aneurysms have unique shapes and dimensions, and vary on ...

Contributors
Hess, Ryan Ambrose, Kleim, Jeff, Nair, Priya, et al.
Created Date
2017-05

The Honors Thesis involved the use of vertically-aligned, piezoelectric nanowire sensor arrays configured by Dr. Henry A. Sodano and Dr. Aneesh Koka from the University of Florida, in order to acquire acceleration data. Originally, the project was focused on interfacing and calibrating the barium titanate (BaTio3) sensors to measure wall shear stress, a fluid dynamic characteristic. In order to gain an understanding of these novel piezoelectric sensors, the experiments performed by Sodano and Koka were to be investigated, replicated, and results reproduced. After initial trial phases, signals failed to be consistently measured from the sensors and the project's emphasis was ...

Contributors
Thomas, Jonah, Frakes, David, LaBelle, Jeffrey, et al.
Created Date
2014-05

Introduction: There are 350 to 400 pediatric heart transplants annually according to the Pediatric Heart Transplant Database (Dipchand et al. 2014). Finding appropriate donors can be challenging especially for the pediatric population. The current standard of care is a donor-to-recipient weight ratio. This ratio is not necessarily a parameter directly indicative of the size of a heart, potentially leading to ill-fitting allografts (Tang et al. 2010). In this paper, a regression model is presented - developed by correlating total cardiac volume to non-invasive imaging parameters and patient characteristics – for use in determining ideal allograft fit with respect to total ...

Contributors
Sajadi, Susan, Lindquist, Jacob, Frakes, David, et al.
Created Date
2016-05

Electroencephalogram (EEG) used simultaneously with video monitoring can record detailed patient physiology during a seizure to aid diagnosis. However, current patient monitoring systems typically require a patient to stay in view of a fixed camera limiting their freedom of movement. The goal of this project is to design an automatic patient monitoring system with software to track patient movement in order to increase a patient’s mobility. This report discusses the impact of an automatic patient monitoring system and the design steps used to create and test a functional prototype.

Contributors
Bui, Robert Truong, Frakes, David, Helms Tillery, Stephen, et al.
Created Date
2014-05

The ability of cochlear implants (CI) to restore auditory function has advanced significantly in the past decade. Approximately 96,000 people in the United States benefit from these devices, which by the generation and transmission of electrical impulses, enable the brain to perceive sound. But due to the predominantly Western cochlear implant market, current CI characterization primarily focuses on improving the quality of American English. Only recently has research begun to evaluate CI performance using other languages such as Mandarin Chinese, which rely on distinct spectral characteristics not present in English. Mandarin, a tonal language utilizes four, distinct pitch patterns, which ...

Contributors
Schiltz, Jessica Hammitt, Berisha, Visar, Frakes, David, et al.
Created Date
2015-05

Glioblastoma Multiforme (GBM) is an aggressive and deadly form of brain cancer with a median survival time of about a year with treatment. Due to the aggressive nature of these tumors and the tendency of gliomas to follow white matter tracks in the brain, each tumor mass has a unique growth pattern. Consequently it is difficult for neurosurgeons to anticipate where the tumor will spread in the brain, making treatment planning difficult. Archival patient data including MRI scans depicting the progress of tumors have been helpful in developing a model to predict Glioblastoma proliferation, but limited scans per patient make ...

Contributors
Snyder, Lena Haley, Kostelich, Eric, Frakes, David, et al.
Created Date
2014-05

A specific type of Congenital Heart Defect (CHD) known as Coarctation (narrowing) of the Aorta (CoA) prevails in 10% of all CHD patients resulting in life-threatening conditions. Treatments involve limited medical therapy (i.e PGE1 therapy), but in majority of CoA cases, planned surgical treatments are very common. The surgical approach is dictated by the severity of the coarctation, by which the method of treatments is divided between minimally invasive and extensive invasive procedures. Modern diagnostic procedures allude to many disadvantages making it difficult for clinical practices to properly deliver an optimal form of care. Computational Fluid Dynamics (CFD) technique addresses ...

Contributors
Pathangey, Girish, Matheny, Chris, Frakes, David, et al.
Created Date
2015-05

Intracranial aneurysms are blood –filled sacs along the blood vessels in the brain. These aneurysms can be particularly dangerous due to difficulty in detection and potential lifethreatening outcome. When these aneurysms are detected, there are few treatment options to prevent rupture, one of which is endovascular stents. By placing a stent across the parent vessel, blood flow can be diverted from the aneurysm. Reduced flow reduces the chance of rupture and promotes clotting within the aneurysm. In this study, hemodynamics in idealized basilar tip aneurysm models were investigated at three flow rates using particle imaging velocimetry (PIV). Two models were ...

Contributors
Chung, Hanseung, Frakes, David, Caplan, Michael, et al.
Created Date
2014-05