Skip to main content

ASU Electronic Theses and Dissertations


This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.




There are many applications for polymer matrix composite materials in a variety of different industries, but designing and modeling with these materials remains a challenge due to the intricate architecture and damage modes. Multiscale modeling techniques of composite structures subjected to complex loadings are needed in order to address the scale-dependent behavior and failure. The rate dependency and nonlinearity of polymer matrix composite materials further complicates the modeling. Additionally, variability in the material constituents plays an important role in the material behavior and damage. The systematic consideration of uncertainties is as important as having the appropriate structural model, especially during …

Contributors
Johnston, Joel Philip, Chattopadhyay, Aditi, Liu, Yongming, et al.
Created Date
2016

The accurate and fast determination of carbon dioxide (CO2) levels is critical for many health and environmental applications. For example, the analysis of CO2 levels in exhaled breath allows for the evaluation of systemic metabolism, perfusion, and ventilation, and provides the doctors and patients with a non-invasive and simple method to predict the presence and severity of asthma, and Chronic Obstructive Pulmonary Disease (COPD). Similarly, the monitoring of CO2 levels in the atmosphere allows for assessment of indoor air quality (IAQ) as the indoor CO2 levels have been proved to be associated with increased prevalence of certain mucous membrane and …

Contributors
Zhao, Di, Forzani, Erica S, Lin, Jerry Ys, et al.
Created Date
2014

This study investigated the efficacy of Early Head Start home-based, center-based and mixed-approach programs on cognitive, language and behavioral outcomes at different levels of cumulative environmental risk. Early Head Start is a federal program that provides low-income families and their children from birth to age three with childcare, parenting education, healthcare and other family supports. As part of Early Head Start's initiation, a program evaluation was begun involving 3,001 children from 17 programs around the country. Half of the children were randomly assigned to the control group, who received no Early Head Start services. Data were collected through program application …

Contributors
Budinger, Susan Martin, Bradley, Robert H, Doane Sampey, Leah D, et al.
Created Date
2012

Windows based mobile application for m-health and environmental monitoring sensor devices were developed and tested. With the number of smartphone users exponentially increasing, the applications developed for m-health and environmental monitoring devices are easy to reach the general public, if the applications are simple, user-friendly and personalized. The sensing device uses Bluetooth to communicate with the smartphone, providing mobility to the user. Since the device is small and hand-held, the user can put his smartphone in his pocket, connected to the device in his hand and can move anywhere with it. The data processing performed in the applications is verified …

Contributors
Ganesan, Srisivapriya, Tao, Nongjian, Zhang, Yanchao, et al.
Created Date
2012

A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene, and xylenes (BTEX) via a homemade molecular imprinted polymer, and a specific detection and control circuit. The device is a wireless, portable, battery-powered, and cell-phone operated device. The device has been calibrated and validated in the laboratory and using selected ion flow tube mass spectrometry (SFIT-MS). The capability and robustness …

Contributors
Chen, Cheng, Tao, Nongjian, Chae, Junseok, et al.
Created Date
2011

Lead is a neurotoxin that has been shown to have a long and lasting impact on the brains, bodies, and behaviors of those who are poisoned. It also has a greater presence in communities with high levels of poverty and minority populations. Compounded over time, the effects of lead poisoning, even at low levels of exposure, impact a child's readiness and ability to learn. To investigate the relationship between the risk of lead poisoning, school level academic achievement, and community demographics, three sets of data were combined. The Lead Poisoning Risk Index (LPRI), used to quantify the risk in each …

Contributors
Gehrman, Matthew Paul, Berliner, David C, Garcia, David, et al.
Created Date
2011