Skip to main content

ASU Electronic Theses and Dissertations


This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.


Status
  • Public
Date Range
2011 2019


ABSTRACT As the technology length shrinks down, achieving higher gain is becoming very difficult in deep sub-micron technologies. As the supply voltages drop, cascodes are very difficult to implement and cascade amplifiers are needed to achieve sufficient gain with required output swing. This sets the fundamental limit on the SNR and hence the maximum resolution that can be achieved by ADC. With the RSD algorithm and the range overlap, the sub ADC can tolerate large comparator offsets leaving the linearity and accuracy requirement for the DAC and residue gain stage. Typically, the multiplying DAC requires high gain wide bandwidth op-amp …

Contributors
Swaminathan, Visu Vaithiyanathan, Barnaby, Hugh, Bakkaloglu, Bertan, et al.
Created Date
2012

The front end of almost all ADCs consists of a Sample and Hold Circuit in order to make sure a constant analog value is digitized at the end of ADC. The design of Track and Hold Circuit (THA) mainly focuses on following parameters: Input frequency, Sampling frequency, dynamic Range, hold pedestal, feed through error. This thesis will discuss the importance of these parameters of a THA to the ADCs and commonly used architectures of THA. A new architecture with SiGe HBT transistors in BiCMOS 130 nm technology is presented here. The proposed topology without complicated circuitry achieves high Spurious Free …

Contributors
Ramakrishna Rao, Nishita Ramakrishna, Barnaby, Hugh, Bakkaloglu, Bertan, et al.
Created Date
2012

Fluxgate sensors are magnetic field sensors that can measure DC and low frequency AC magnetic fields. They can measure much lower magnetic fields than other magnetic sensors like Hall effect sensors, magnetoresistive sensors etc. They also have high linearity, high sensitivity and low noise. The major application of fluxgate sensors is in magnetometers for the measurement of earth's magnetic field. Magnetometers are used in navigation systems and electronic compasses. Fluxgate sensors can also be used to measure high DC currents. Integrated micro-fluxgate sensors have been developed in recent years. These sensors have much lower power consumption and area compared to …

Contributors
Pappu, Karthik, Bakkaloglu, Bertan, Christen, Jennifer Blain, et al.
Created Date
2013

Developing countries suffer from various health challenges due to inaccessible medical diagnostic laboratories and lack of resources to establish new laboratories. One way to address these issues is to develop diagnostic systems that are suitable for the low-resource setting. In addition to this, applications requiring rapid analyses further motivates the development of portable, easy-to-use, and accurate Point of Care (POC) diagnostics. Lateral Flow Immunoassays (LFIAs) are among the most successful POC tests as they satisfy most of the ASSURED criteria. However, factors like reagent stability, reaction rates limit the performance and robustness of LFIAs. The fluid flow rate in LFIA …

Contributors
Thamatam, Nipun, Christen, Jennifer Blain, Goryll, Michael, et al.
Created Date
2019

Intracellular voltage recordings from single neurons in vitro and in vivo have been fundamental to our understanding of neuronal function. Conventional electrodes and associated positioning systems for intracellular recording in vivo are large and bulky, which has largely restricted their use to single-channel recording from anesthetized animals. Further, intracellular recordings are very cumbersome, requiring a high degree of skill not readily achieved in a typical laboratory. This dissertation presents a robotic, head-mountable, MEMS (Micro-Electro-Mechanical Systems) based intracellular recording system to overcome the above limitations associated with form-factor, scalability and highly skilled and tedious manual operations required for intracellular recordings. This …

Contributors
Sampath Kumar, Swathy, Muthuswamy, Jit, Abbas, James, et al.
Created Date
2018

The past two decades have been monumental in the advancement of microchips designed for a diverse range of medical applications and bio-analysis. Owing to the remarkable progress in micro-fabrication technology, complex chemical and electro-mechanical features can now be integrated into chip-scale devices for use in biosensing and physiological measurements. Some of these devices have made enormous contributions in the study of complex biochemical processes occurring at the molecular and cellular levels while others overcame the challenges of replicating various functions of human organs as implant systems. This thesis presents test data and analysis of two such systems. First, an ISFET …

Contributors
Mamun, Samiha, Christen, Jennifer Blain, Goryll, Michael, et al.
Created Date
2011

Due to heterogeneity at the cellular level, single cell analysis (SCA) has become a necessity to study cellomics for the early detection of diseases like cancer. Development of single cell manipulation systems is very critical for performing SCA. In this thesis, electrorotation (ROT) chips to trap and rotate single cells using electrokinetic forces have been developed. The ROT chip mainly consists of a set of closely spaced metal electrodes (60µm interspacing between opposite electrodes) that forms a closed electric field cage (electrocage) when driven with high frequency AC voltages. Cells were flowed through a microchannel to the electrocage where they …

Contributors
Soundappa Elango, Iniyan, Meldrum, Deirdre R, Christen, Jennifer Blain, et al.
Created Date
2012

Test cost has become a significant portion of device cost and a bottleneck in high volume manufacturing. Increasing integration density and shrinking feature sizes increased test time/cost and reduce observability. Test engineers have to put a tremendous effort in order to maintain test cost within an acceptable budget. Unfortunately, there is not a single straightforward solution to the problem. Products that are tested have several application domains and distinct customer profiles. Some products are required to operate for long periods of time while others are required to be low cost and optimized for low cost. Multitude of constraints and goals …

Contributors
Yilmaz, Ender, Ozev, Sule, Bakkaloglu, Bertan, et al.
Created Date
2012

Micro-Electro Mechanical System (MEMS) is the micro-scale technology applying on various fields. Traditional testing strategy of MEMS requires physical stimulus, which leads to high cost specified equipment. Also there are a large number of wafer-level measurements for MEMS. A method of estimation calibration coefficient only by electrical stimulus based wafer level measurements is included in the thesis. Moreover, a statistical technique is introduced that can reduce the number of wafer level measurements, meanwhile obtaining an accurate estimate of unmeasured parameters. To improve estimation accuracy, outlier analysis is the effective technique and merged in the test flow. Besides, an algorithm for …

Contributors
Deng, Lingfei, Ozev, Sule, Yu, Hongyu, et al.
Created Date
2012

Different environmental factors, such as ultraviolet radiation (UV), relative humidity (RH) and the presence of reducing gases (acetone and ethanol), play an important role in the daily life of human beings. UV is very important in a number of areas, such as astronomy, resin curing of polymeric materials, combustion engineering, water purification, flame detection and biological effects with more recent proposals like early missile plume detection, secure space-to-space communications and pollution monitoring. RH is a very common parameter in the environment. It is essential not only for human comfort, but also for a broad spectrum of industries and technologies. There …

Contributors
Qiu, Xiaotun, Yu, Hongyu, Christen, Jennifer Blain, et al.
Created Date
2011

The first part describes Metal Semiconductor Field Effect Transistor (MESFET) based fundamental analog building blocks designed and fabricated in a single poly, 3-layer metal digital CMOS technology utilizing fully depletion mode MESFET devices. DC characteristics were measured by varying the power supply from 2.5V to 5.5V. The measured DC transfer curves of amplifiers show good agreement with the simulated ones with extracted models from the same process. The accuracy of the current mirror showing inverse operation is within ±15% for the current from 0 to 1.5mA with the power supply from 2.5 to 5.5V. The second part presents a low-power …

Contributors
Kim, Sung Ho, Bakkaloglu, Bertan, Christen, Jennifer Blain, et al.
Created Date
2011

Flexible hybrid electronics (FHE) is emerging as a promising solution to combine the benefits of printed electronics and silicon technology. FHE has many high-impact potential areas, such as wearable applications, health monitoring, and soft robotics, due to its physical advantages, which include light weight, low cost and the ability conform to different shapes. However, physical deformations that can occur in the field lead to significant testing and validation challenges. For example, designers have to ensure that FHE devices continue to meet specs even when the components experience stress due to bending. Hence, physical deformation, which is hard to emulate, has …

Contributors
Gao, Hang, Ozev, Sule, Ogras, Umit Y, et al.
Created Date
2018

Coarse Grain Reconfigurable Arrays (CGRAs) are promising accelerators capable of achieving high performance at low power consumption. While CGRAs can efficiently accelerate loop kernels, accelerating loops with control flow (loops with if-then-else structures) is quite challenging. Techniques that handle control flow execution in CGRAs generally use predication. Such techniques execute both branches of an if-then-else structure and select outcome of either branch to commit based on the result of the conditional. This results in poor utilization of CGRA s computational resources. Dual-issue scheme which is the state of the art technique for control flow fetches instructions from both paths of …

Contributors
Rajendran Radhika, Shri Hari, Shrivastava, Aviral, Christen, Jennifer Blain, et al.
Created Date
2014

Obtaining local electrochemical (EC) information is extremely important for understanding basic surface reactions, and for many applications. Scanning electrochemical microscopy (SECM) can obtain local EC information by scanning a microelectrode across the surface. Although powerful, SECM is slow, the scanning microelectrode may perturb reaction and the measured signal decreases with the size of microelectrode. This thesis demonstrates a new imaging technique based on a principle that is completely different from the conventional EC detection technologies. The technique, referred to as plasmonic-based electrochemical imaging (PECI), images local EC current (both faradaic and non-faradaic) without using a scanning microelectrode. Because PECI response …

Contributors
Shan, Xiaonan, Tao, Nongjian, Chae, Junseok, et al.
Created Date
2011

Accessibility to the internal nodes of an analog/mixed-signal circuit while testing is extremely difficult. Furthermore, with technology scaling, the effect of process variations becomes more pronounced which in turn effects the test time, test cost, and die yield. As devices become more unreliable, the probability of failure of a die increases, yield decreases affecting the quality of test and cost.Therefore, test time minimization and test cost reduction are important. Moreover, process variations can affect the performance of analog/mixed circuits. Therefore, the performance of a System On-Chip(SoC) which tends to integrate multiple band gap reference circuits (BGRs) is effected due to …

Contributors
Ravouri, Yestina, Ozev, Sule, Ogras, Umit, et al.
Created Date
2017

Alternative computation based on neural systems on a nanoscale device are of increasing interest because of the massive parallelism and scalability they provide. Neural based computation systems also offer defect finding and self healing capabilities. Traditional Von Neumann based architectures (which separate the memory and computation units) inherently suffer from the Von Neumann bottleneck whereby the processor is limited by the number of instructions it fetches. The clock driven based Von Neumann computer survived because of technology scaling. However as transistor scaling is slowly coming to an end with channel lengths becoming a few nanometers in length, processor speeds are …

Contributors
Sivaraj, Mahraj, Barnaby, Hugh James, Kozicki, Michael, et al.
Created Date
2015

Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis. Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and detecting seizure zones. However, ECoG electrodes cause a foreign body mass effect, swelling, and pneumocephaly, which results in elevation of intracranial pressure (ICP). Thus, the aim of this work is to design an intracranial pressure monitoring system that could augment ECoG electrodes. A minimally invasive, low-cost epidural intracranial pressure monitoring …

Contributors
Sampath Kumaran, Ranjani, Christen, Jennifer Blain, Tillery, Stephen Helms, et al.
Created Date
2015