Skip to main content

ASU Electronic Theses and Dissertations


This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.


Resource Type
  • Masters Thesis
Date Range
2010 2015


Microelectrodes have been used as the neural interface to record brain's neural activities. Most of these electrodes are fixed positioned. Neural signal normally degrades over time due to the body immune response and brain micromotion that move the neurons away from the microelectrode. MEMS technology under SUMMiT VTM processes has developed miniaturized version of moveable microelectrodes that have the ability to recover the neural signal degradation by searching new cluster of neurons. To move the MEMS microelectrode a combination of four voltage waveforms must be applied to four thermally actuated microactuators. Previous design has used OmneticTM interconnect to transfer the …

Contributors
Tee, Zikai, Muthuswamy, Jitendran, Sutanto, Jemmy, et al.
Created Date
2012

"Sensor Decade" has been labeled on the first decade of the 21st century. Similar to the revolution of micro-computer in 1980s, sensor R&D; developed rapidly during the past 20 years. Hard workings were mainly made to minimize the size of devices with optimal the performance. Efforts to develop the small size devices are mainly concentrated around Micro-electro-mechanical-system (MEMS) technology. MEMS accelerometers are widely published and used in consumer electronics, such as smart phones, gaming consoles, anti-shake camera and vibration detectors. This study represents liquid-state low frequency micro-accelerometer based on molecular electronic transducer (MET), in which inertial mass is not the …

Contributors
Liang, Mengbing, Yu, Hongyu, Jiang, Hanqing, et al.
Created Date
2013

Advances in miniaturized sensors and wireless technologies have enabled mobile health systems for efficient healthcare. A mobile health system assists the physician to monitor the patient's progress remotely and provide quick feedbacks and suggestions in case of emergencies, which reduces the cost of healthcare without the expense of hospitalization. This work involves development of an innovative mobile health system with adaptive biofeedback mechanism and demonstrates the importance of biofeedback in accurate measurements of physiological parameters to facilitate the diagnosis in mobile health systems. Resting Metabolic Rate (RMR) assessment, a key aspect in the treatment of diet related health problems is …

Contributors
Krishnan, Ranganath, Tao, Nongjian, Forzani, Erica, et al.
Created Date
2012

Negative bias temperature instability (NBTI) and channel hot carrier (CHC) are important reliability issues impacting analog circuit performance and lifetime. Compact reliability models and efficient simulation methods are essential for circuit level reliability prediction. This work proposes a set of compact models of NBTI and CHC effects for analog and mixed-signal circuit, and a direct prediction method which is different from conventional simulation methods. This method is applied in circuit benchmarks and evaluated. This work helps with improving efficiency and accuracy of circuit aging prediction. Dissertation/Thesis

Contributors
Zheng, Rui, Cao, Yu, Yu, Hongyu, et al.
Created Date
2011

The past two decades have been monumental in the advancement of microchips designed for a diverse range of medical applications and bio-analysis. Owing to the remarkable progress in micro-fabrication technology, complex chemical and electro-mechanical features can now be integrated into chip-scale devices for use in biosensing and physiological measurements. Some of these devices have made enormous contributions in the study of complex biochemical processes occurring at the molecular and cellular levels while others overcame the challenges of replicating various functions of human organs as implant systems. This thesis presents test data and analysis of two such systems. First, an ISFET …

Contributors
Mamun, Samiha, Christen, Jennifer Blain, Goryll, Michael, et al.
Created Date
2011

Micro-Electro Mechanical System (MEMS) is the micro-scale technology applying on various fields. Traditional testing strategy of MEMS requires physical stimulus, which leads to high cost specified equipment. Also there are a large number of wafer-level measurements for MEMS. A method of estimation calibration coefficient only by electrical stimulus based wafer level measurements is included in the thesis. Moreover, a statistical technique is introduced that can reduce the number of wafer level measurements, meanwhile obtaining an accurate estimate of unmeasured parameters. To improve estimation accuracy, outlier analysis is the effective technique and merged in the test flow. Besides, an algorithm for …

Contributors
Deng, Lingfei, Ozev, Sule, Yu, Hongyu, et al.
Created Date
2012

The RADiation sensitive Field Effect Transistor (RADFET) has been conventionally used to measure radiation dose levels. These dose sensors are calibrated in such a way that a shift in threshold voltage, due to a build-up of oxide-trapped charge, can be used to estimate the radiation dose. In order to estimate the radiation dose level using RADFET, a wired readout circuit is necessary. Using the same principle of oxide-trapped charge build-up, but by monitoring the change in capacitance instead of threshold voltage, a wireless dose sensor can be developed. This RADiation sensitive CAPacitor (RADCAP) mounted on a resonant patch antenna can …

Contributors
Srinivasan Gopalan, Madusudanan, Barnaby, Hugh, Holbert, Keith, et al.
Created Date
2010

In this thesis, an approach to develop low-frequency accelerometer based on molecular electronic transducers (MET) in an electrochemical cell is presented. Molecular electronic transducers are a class of inertial sensors which are based on an electrochemical mechanism. Motion sensors based on MET technology consist of an electrochemical cell that can be used to detect the movement of liquid electrolyte between electrodes by converting it to an output current. Seismometers based on MET technology are attractive for planetary applications due to their high sensitivity, low noise, small size and independence on the direction of sensitivity axis. In addition, the fact that …

Contributors
Zhao, Zuofeng, Yu, Hongyu, Zhang, Junshan, et al.
Created Date
2015

ABSTRACT Electronics especially mobile electronics such as smart phones, tablet PCs, notebooks and digital cameras are undergoing rapid development nowadays and have thoroughly changed our lives. With the requirement of more transistors, higher power, smaller size, lighter weight and even bendability, thermal management of these devices became one of the key challenges. Compared to active heat management system, heat pipe, which is a passive fluidic system, is considered promising to solve this problem. However, traditional heat pipes have size, weight and capillary limitation. Thus new type of heat pipe with smaller size, lighter weight and higher capillary pressure is needed. …

Contributors
Sun, Tianwei, Jiang, Hanqing, Yu, Hongyu, et al.
Created Date
2014

This thesis is a study of Bandwidth limitation of basestation power amplifier and its Doherty application. Fundamentally, bandwidth of a power amplifier (PA) is limited by both its input and output prematch networks and its Doherty architecture, specifically the impedance inverter between the main and auxiliary amplifier. In this study, only the output prematch network and the Doherty architecture follows are being investigated. A new proposed impedance inverter in the Doherty architecture exhibits an extended bandwidth compared to traditional quarterwave line. Base on the loadline analysis, output impedance of the power amplifier can be represented by a loadline resistor and …

Contributors
Yang, Nick, Pan, George, Pan, George, et al.
Created Date
2014