This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.


Language
  • English
Resource Type
Status
  • Public
Subject
Date Range
2010 2014


This thesis presents a gas sensor readout IC for amperometric and conductometric electrochemical sensors. The Analog Front-End (AFE) readout circuit enables tracking long term exposure to hazardous gas fumes in diesel and gasoline equipments, which may be correlated to diseases. Thus, the detection and discrimination of gases using microelectronic gas sensor system is required. This thesis describes the research, development, implementation and test of a small and portable based prototype platform for chemical gas sensors to enable a low-power and low noise gas detection system. The AFE reads out the outputs of eight conductometric sensor array and eight amperometric sensor …

Contributors
Kim, Hyuntae, Bakkaloglu, Bertan, Vermeire, Bert, et al.
Created Date
2011

The development of a Solid State Transformer (SST) that incorporates a DC-DC multiport converter to integrate both photovoltaic (PV) power generation and battery energy storage is presented in this dissertation. The DC-DC stage is based on a quad-active-bridge (QAB) converter which not only provides isolation for the load, but also for the PV and storage. The AC-DC stage is implemented with a pulse-width-modulated (PWM) single phase rectifier. A unified gyrator-based average model is developed for a general multi-active-bridge (MAB) converter controlled through phase-shift modulation (PSM). Expressions to determine the power rating of the MAB ports are also derived. The developed …

Contributors
Falcones, Sixifo Daniel, Ayyanar, Raja, Karady, George, et al.
Created Date
2011

As the world energy demand increases, semiconductor devices with high energy conversion efficiency become more and more desirable. The energy conversion consists of two distinct processes, namely energy generation and usage. In this dissertation, novel multi-junction solar cells and light emitting diodes (LEDs) are proposed and studied for high energy conversion efficiency in both processes, respectively. The first half of this dissertation discusses the practically achievable energy conversion efficiency limit of solar cells. Since the demonstration of the Si solar cell in 1954, the performance of solar cells has been improved tremendously and recently reached 41.6% energy conversion efficiency. However, …

Contributors
Wu, Songnan, Zhang, Yong-Hang, Menendez, Jose, et al.
Created Date
2010

A dual-channel directional digital hearing aid (DHA) front end using Micro Electro Mechanical System (MEMS) microphones and an adaptive-power analog processing signal chain is presented. The analog front end consists of a double differential amplifier (DDA) based capacitance to voltage conversion circuit, 40dB variable gain amplifier (VGA) and a continuous time sigma delta analog to digital converter (CT - ΣΔ ADC). Adaptive power scaling of the 4th order CT - ΣΔ achieves 68dB SNR at 120μW, which can be scaled down to 61dB SNR at 67μW. This power saving will increse the battery life of the DHA. Dissertation/Thesis

Contributors
Deligoz, Ilker, Kiaei, Sayfe, Bakkaloglu, Bertan, et al.
Created Date
2010

Magnetic resonance (MR) imaging with data acquisition on a non-rectangular grid permits a variety of approaches to cover k-space. This flexibility can be exploited to achieve clinically relevant characteristics -- fast yet full coverage for short scan times, center out schemes for short Te, over-sampled k-space for robustness to motion, long acquisition time for improved signal-to-noise (SNR) performance and benign under-sampling (aliasing) artifact. This dissertation presents advances in Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) trajectory design and improved reconstruction for spiral imaging. Scan time in PROPELLER imaging can be reduced by tailoring the trajectory to the required …

Contributors
Devaraj, Ajit, Pipe, James G, Karam, Lina J, et al.
Created Date
2010

As existing solar cell technologies come closer to their theoretical efficiency, new concepts that overcome the Shockley-Queisser limit and exceed 50% efficiency need to be explored. New materials systems are often investigated to achieve this, but the use of existing solar cell materials in advanced concept approaches is compelling for multiple theoretical and practical reasons. In order to include advanced concept approaches into existing materials, nanostructures are used as they alter the physical properties of these materials. To explore advanced nanostructured concepts with existing materials such as III-V alloys, silicon and/or silicon/germanium and associated alloys, fundamental aspects of using these …

Contributors
Dahal, Som Nath, Honsberg, Christiana, Goodnick, Stephen, et al.
Created Date
2011

Demand for biosensor research applications is growing steadily. According to a new report by Frost & Sullivan, the biosensor market is expected to reach $14.42 billion by 2016. Clinical diagnostic applications continue to be the largest market for biosensors, and this demand is likely to continue through 2016 and beyond. Biosensor technology for use in clinical diagnostics, however, requires translational research that moves bench science and theoretical knowledge toward marketable products. Despite the high volume of academic research to date, only a handful of biomedical devices have become viable commercial applications. Academic research must increase its focus on practical uses …

Contributors
Choi, Seokheun, Chae, Junseok, Tao, Nongjian, et al.
Created Date
2011

Programmable Metallization Cell (PMC) is a resistance-switching device based on migration of nanoscale quantities of cations in a solid electrolyte and formation of a conducting electrodeposit by the reductions of these cations. This dissertation presents electrical characterization results on Cu-SiO2 based PMC devices, which due to the na- ture of materials can be easily integrated into the current Complimentary metal oxide semiconductor (CMOS) process line. Device structures representing individual mem- ory cells based on W bottom electrode and n-type Si bottom electrode were fabricated for characterization. For the W bottom electrode based devices, switching was ob- served for voltages in …

Contributors
Puthenthermadam, Sarath, Kozicki, Michael N, Diaz, Rodolfo, et al.
Created Date
2011

Graphene, a one atomic thick planar sheet of carbon atoms, has a zero gap band structure with a linear dispersion relation. This unique property makes graphene a favorite for physicists and engineers, who are trying to understand the mechanism of charge transport in graphene and using it as channel material for field effect transistor (FET) beyond silicon. Therefore, an in-depth exploring of these electrical properties of graphene is urgent, which is the purpose of this dissertation. In this dissertation, the charge transport and quantum capacitance of graphene were studied. Firstly, the transport properties of back-gated graphene transistor covering by high …

Contributors
Xia, Jilin, Tao, N.J., Ferry, David, et al.
Created Date
2010

Silicon carbide (SiC), long touted as a material that can satisfy the specific property requirements for high temperature and high power applications, was studied quantitatively using various techniques. The electronic band structure of 4H SiC is examined in the first half of this dissertation. A brief introduction to band structure calculations, with particular emphasis on the empirical pseudopotential method, is given as a foundation for the subsequent work. Next, the crystal pseudopotential for 4H SiC is derived in detail, and a novel approach using a genetic algorithm search routine is employed to find the fitting parameters needed to generate the …

Contributors
Ng, Garrick, Schroder, Dieter K, Vasileska, Dragica, et al.
Created Date
2010