Skip to main content

ASU Electronic Theses and Dissertations


This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.


The need for rapid, specific and sensitive assays that provide a detection of bacterial indicators are important for monitoring water quality. Rapid detection using biosensor is a novel approach for microbiological testing applications. Besides, validation of rapid methods is an obstacle in adoption of such new bio-sensing technologies. In this study, the strategy developed is based on using the compound 4-methylumbelliferyl glucuronide (MUG), which is hydrolyzed rapidly by the action of E. coli β-D-glucuronidase (GUD) enzyme to yield a fluorogenic product that can be quantified and directly related to the number of E. coli cells present in water samples. The …

Contributors
Hesari, Nikou, Abbaszadegan, Morteza, Alum, Absar, et al.
Created Date
2015

Advanced oxidation processes (AOP’s) are water/wastewater treatment processes simultaneously providing disinfection and potential oxidation of contaminants that may cause long-term adverse health effects in humans. One AOP involves injecting peracetic acid (PAA) upstream of an ultraviolet (UV) irradiation reactor. Two studies were conducted, one in pilot-scale field conditions and another under laboratory conditions. A pilot-scale NeoTech UV reactor (rated for 375 GPM) was used in the pilot study, where a smaller version of this unit was used in the laboratory study (20 to 35 GPM). The pilot study analyzed coliform disinfection and also monitored water quality parameters including UV transmittance …

Contributors
Cooper, Samantha L., Abbaszadegan, Morteza, Alum, Absar, et al.
Created Date
2017

This study was designed to provide insight into microbial transport kinetics which might be applied to bioremediation technology development and prevention of groundwater susceptibility to pathogen contamination. Several pilot-scale experiments were conducted in a saturated, 2 dimensional, packed porous media tank to investigate the transport of Escherichia coli bacteria, P22 bacteriophage, and a visual tracer and draw comparisons and/or conclusions. A constructed tank was packed with an approximate 3,700 cubic inches (in3) of a fine grained, homogeneous, chemically inert sand which allowed for a controlled system. Sampling ports were located at 5, 15, 25, and 25 vertical inches from the …

Contributors
Acosta, Jazlyn Cauren, Abbaszadegan, Morteza, Dahlen, Paul, et al.
Created Date
2017